PINNED
Max VCG for specific loadcase (like limit VCG) analysis
Add new functionality to Large Angle Stability analysis so that a single fixed-weight item in the loadcase can be selected so that automatically the maximum VCG of that item can be found for which the GZ curve still (just) passes all selected stab...
Option to check and remove the irregular frequencies
Irregular frequencies give rise to unusual results. Since Moses is a complete hydrodynamic modelling and analysis software, it would be really helpful if there was an option to check for and remove the irregular frequencies. Otherwise, the feature...
Max VCG for specific loadcase (like limit VCG) analysis
Add new functionality to Large Angle Stability analysis so that a single fixed-weight item in the loadcase can be selected so that automatically the maximum VCG of that item can be found for which the GZ curve still (just) passes all selected stab...
The command &convert does not convert the SACS cards: Keep, Delete, Dummy. Many SACS users are now preferring these cards for modeling. Converting the SACS model to MOSES without these cards creates friction within the project workflow. Please...
In many projects, the cargo being transported starts as a SACS model. This model is translated to MOSES. Most of the time the model is not changed in MOSES. MOSES can now create a .vue database that is read by MOSES Precede. MOSES Precede is a ver...
Multiframe has Primary and secondary serviceability checks. But often there needs to be more than 2 checks that requires multiple runs of the design to check each desired case. Can Multiframe have tertiary or even four checks for serviceability.
It would be very timesaving if Multiframe results could stream to a specified Word template file rather than just it creating its own file. The template would then be able to have company header to match other computation sheets.
Allow for full directional wave spectra to enable forecast or measured directional wave spectra to be analysed. First step towards this could be to increase the limitation on 1D wave spectra -sea and -a_sea from 5 total to a significantly larger n...
To better automate tasks a VBA method that given the two view angles, a zoom level and the data type (bendingx, von mises .ect) will take a screen shot of the plot window and copy that to the clipboard so it can be placed in a report/excel file. T...
We would like to have the option to define ring stiffeners in tubular members. Currently we are limited to TUBE, CONE, BOX, WBOX, PRI, IBEAM, G_IBEAM, TEE, CHANNEL, ANGLE_D, LLEG or PLATE.